2.5 Cooling
Fans
The Cooling Fan assembly (located beneath the Take-Up Roller) contains
fans that cool the substrate before it rolls on the Take-Up Roller. The
Cooling Fan Assembly automatically switches on when the machine is put
into RUN mode.
2.6 Draw-Down
Applicator
The Draw-Down Applicator is used to apply and smooth the sealant onto
the surface of the substrate. The Draw-Down Applicator is automatically
lowered when the machine is put into RUN mode, and will rise when not
in RUN mode.
2.7 Dryer
Panel
The Dryer Panel is constructed of two infrared heaters used to dry and
cure the sealant, as the substrate passes underneath.
The Dryer Panel is in the DOWN position only if all the following
conditions apply:
The machine is in RUN mode.
The Dryer Panel Switch on the Control Panel is set to DOWN.
The Run Drive is ON.
There is no obstruction blocking any of the Photo Eyes.
NOTE:
The Dryer Panel has fans in the top of it that force air through perforations in
the face of the heaters. These fans are used to push humidity away from the
substrate as it passes underneath the Dryer Panel. IT IS VERY IMPORTANT THAT
THE FANS REMAIN UNOBSTRUCTED.
2.8
Emergency Stop Buttons
There are three red Emergency Stop Buttons. When any of the three
buttons are pressed, all control power shuts down, and the
pneumatically controlled Dryer Panel and Draw-Down Applicator return
to UP position. The machine cannot be used again until the Emergency
Stop Buttons are reset by twisting the button that was initially pressed
one-quarter (¼) turn clockwise. Resetting the Emergency Stop Buttons
returns the coater to an initial power ON stage.