DAC-2202 Antenna Control Unit
Maintenance & Troubleshooting
8-9
8
The
M&C Baudrate
field displays the J3 M&C Port Baud rate value currently stored in the Comm
IF Module. To change the Baud rate, type in the desired value and click on the
SUBMIT
button or
click on the
SAVE
button to store value to Flash. Acceptable baud rate values are 4800 or 9600.
9
The
NMEA A Baudrate
field displays the J2 NMEA Port A Baud rate value currently stored in the
Comm IF Module. To change the Baud rate, type in the desired value and click on the
SUBMIT
button or click on the
SAVE
button to store value to Flash. Acceptable baud rate values are 4800
or 9600.
10
The
NMEA B Baudrate
field displays the J2 NMEA Port B Baud rate value currently stored in the
Comm IF Module. To change the Baud rate, type in the desired value and click on the
SUBMIT
button or click on the
SAVE
button to store value to Flash. Acceptable baud rate values are 4800
or 9600.
11
The
LO Band 1
field displays a drop down selection list for the Local Oscillator value to be used
when Band 1 is selected for tracking purposes.
12
The
LO Band 2
field displays a drop down selection list for the Local Oscillator value to
be used when Band 2 is selected for tracking purposes.
13
The
LO Band 3
field displays a drop down selection list for the Local Oscillator value to
be used when Band 3 is selected for tracking purposes.
14
The
LO Band 4
field displays a drop down selection list for the Local Oscillator value to
be used when Band 4 is selected for tracking purposes.
15
The
NMEA Heading ID
displays a drop down selection list for NMEA 0183 compliant heading
inputs into the ACU.
Current selections available are HDT, HDM, HDD, & HDG.
16
Click the
SUBMIT
button to transfer all currently displayed parameters to the Comm IF module
operating software variables table. NOTE: The submit button will not store the values to NVRAM;
an ACU reset or power cycle will revert to the settings saved in memory.
17
Click the
SAVE
button to store all current parameters in the operating software variables table to
Flash (Comm IF).
**THIS DOES NOT SAVE DISPLAYED PARAMETERS UNLESS THE SUBMIT BUTTON IS PRESSED
FIRST**
18
The
Command
field displays an entry field for line based utility or configuration commands.
Enter in the desired command string and then select the
Send
button to submit the command.
For a complete list of available commands, refer to your antenna manual or the appropriate
command set documentation
19
The
Response
field displays a display value or string based, whenever a sent remote command
involves a displayed response.
Summary of Contents for DAC-2202
Page 8: ...Introduction DAC 2202 Antenna Control Unit 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 32: ...Installation DAC 2202 Antenna Control Unit 4 6 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...Functional Testing DAC 2202 Antenna Control Unit 6 4 This Page Intentionally Left Blank ...
Page 106: ...Technical Specifications DAC 2202 Antenna Control Unit 9 6 This Page Intentionally Left Blank ...
Page 108: ...Drawings DAC 2202 Antenna Control Unit 10 2 This Page Intentionally Left Blank ...
Page 113: ......
Page 114: ......
Page 115: ......