Diagnostic M&C Software Installation & Use
DAC-2202 Antenna Control Unit
7-34
If “Searching for boards on port 3000.” continuously
displays on bottom dialog box after sending Ping
Request, then the Comm IF PCB is NOT communicating
with computers Ethernet port.
Possible Failure: Network Download Utility not
configured correctly.
Check: Verify IP address and Port Number entered in
step 11 matches that of the ACU. (Factory Default IP
address is 192.168.30.195 with a Subnet mask of
255.255.255.248).
Check: Verify “RAM Loader” and “User Program”
parameters entered are properly loaded.
Possible Failure: Laptop Ethernet Port settings not
configured correctly.
Check: Verify computer LAN port has been configured
with a static IP address on the same Subnet as
DAC2x02.
Verify ability to Ping ACU Ethernet Port using windows
Command Prompt.
Click on “Download” in the upper right hand corner to
start the download process.
Verify dialog box displays “Download Complete:)”
Verify the Network Download Utility sends a Reboot
command to the ACU and that the ACU echo’s back
“Board at 192.168.30.195 is rebooting”.
Close Network Download Utility by clicking on “Exit”.
Summary of Contents for DAC-2202
Page 8: ...Introduction DAC 2202 Antenna Control Unit 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 32: ...Installation DAC 2202 Antenna Control Unit 4 6 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...Functional Testing DAC 2202 Antenna Control Unit 6 4 This Page Intentionally Left Blank ...
Page 106: ...Technical Specifications DAC 2202 Antenna Control Unit 9 6 This Page Intentionally Left Blank ...
Page 108: ...Drawings DAC 2202 Antenna Control Unit 10 2 This Page Intentionally Left Blank ...
Page 113: ......
Page 114: ......
Page 115: ......