SV600 Series User Manual 6 Parameters List
69
Group PP : Function Code Management
Function
code
Name
Setting range
Default
Property
PP-00
User password
0-65535
0
☆
PP-01
Parameter initialization
0: No action
01: Restore factory settings, excluding motor
parameters
02: Clear record information
04: Back up user current parameters
501: Restore user backup parameters
0
★
PP-02
Function parameter group
display selection
Units digit: U Group Display Selection
0: Not display
1: Display
Tens digit: Group A Display Selection
0: Not display
1: Display
11
★
PP-03
Reserved
PP-04
Function code
modification property
0: Modifiable
1: Not modifiable
0
☆
Group A0: Torque Control Parameters
Function
code
Name
Setting range
Default
Property
A0-00
Speed/Torque control
selection
0: Speed control
1: Torque control
0
★
A0-01
Torque setting source
selection
0: Set by A0-03
1: AI1
2: AI2
3: Reserved
4: PULSE setting (HDI)
5: Communication setting
6: MIN (AI1, AI2)
7: MAX (AI1, AI2)
(100% of 1-7 options, corresponding to the value set in
A0-03)
0
★
A0-03
Torque digital setting
-200.0% ~ 200.0%
150.0%
☆
A0-05
Forward maximum
frequency of torque
control
0.00 Hz ~ maximum frequency
50.00 Hz
☆
A0-06
Reverse maximum
frequency of torque
control
0.00 Hz ~ maximum frequency
50.00 Hz
☆
A0-07
Torque control
acceleration time
0.00 s ~ 65000 s
0.00 s
☆
A0-08
Torque control
deceleration time
0.00 s ~ 65000 s
0.00 s
☆
Group A1: Virtual IO
Function
code
Name
Setting range
Default
Property
A1-00
VDI1 function selection
0 ~ 59
0
★
A1-01
VDI2 function selection
0 ~ 59
0
★