SV600 Series User Manual 2 Product Introduction
11
Protection function
Short circuit detection, short circuit to ground detection, input and
output
loss
phase
detection,
overcurrent,
overvoltage,
undervoltage, overheat, overload, underload, contactor protection,
terminals protection and so on.
A
m
b
ie
n
t
Use ambient
Indoor, not bare to sunlight, no dust, no corrosive gas, no
flammable gas, no vapor, no water drop or salt etc.
Altitude
Less than 1000 meters.
(
10% de-rating using for each 1000 meters
when over 1000 meters.)
Ambient temperature
-10
℃ ~
+40
℃
(under ambient temperature 40
℃ ~
50
℃
,please
reduce the volume or strengthen heat sink)
Ambient humidity
Less than 95%RH
,
without condenses
Vibration
Smaller than5.9m/s
²
(0.6g)
Storage temperature
-40
℃~
+70
℃
S
tr
u
ct
u
re
Defending grade
IP20
Cooling mode
Forced air cooling and fan controls with temperature
Mounting mode
Wall hangning or install in cabinet