7 Parameter Description SV600 Series User Manual
144
When the counting value reaches the count value (Pb-09), the DO terminal allocated with function
9 (count value reached) becomes ON. Then the counter continues to count until the set count
value is reached.
Pb-09 should be equal to or smaller than Pb-08.
Fig.7-30 Counting function setting
Group PC: Multi-segment instruction, simple PLC functions
Multi-segment instruction has many functions. Besides multi-speed, it can be used as the setting
source of the V/F separated voltage source and setting source of process PID. And iIt's relative
value.
Simple PLC function can complete total maximum 16 steps with combination of multi-speed,
Function
code
Name
Setting range
Default
Property
PC-00
Multi-segment instruction 0
-100.0% ~ 100.0%
(100% corresponds to frequency set in
P0-10)
10.0%
☆
PC-01
Multi-segment instruction 1
-100% ~ 100%
20.0%
☆
PC-02
Multi-segment instruction 2
-100% ~ 100%
30.0%
☆
PC-03
Multi-segment instruction 3
-100% ~ 100%
40.0%
☆
PC-04
Multi-segment instruction 4
-100% ~ 100%
50.0%
☆
PC-05
Multi-segment instruction 5
-100% ~ 100%
60.0%
☆
PC-06
Multi-segment instruction 6
-100% ~ 100%
70.0%
☆
PC-07
Multi-segment instruction 7
-100% ~ 100%
80.0%
☆
PC-08
Multi-segment instruction 8
-100% ~ 100%
90.0%
☆
PC-09
Multi-segment instruction 9
-100% ~ 100%
100.0%
☆
PC-10
Multi-segment instruction 10
-100% ~ 100%
100.0%
☆
PC-11
Multi-segment instruction 11
-100% ~ 100%
100.0%
☆
PC-12
Multi-segment instruction 12
-100% ~ 100%
100.0%
☆
PC-13
Multi-segment instruction 13
-100% ~ 100%
100.0%
☆
PC-14
Multi-segment instruction 14
-100% ~ 100%
100.0%
☆