P/N 595189-01 Rev A 4/10
regulAr oPerATionAl inSPecTion
conTinued on nexT PAge...
cAuTion
if The noSe cuP iS removed for inSPec-
Tion, mAKe cerTAin iT iS reASSembled
correcTly for The model fAcePiece
And STyle of noSe cuP.
figure 10
checking voicemitter ducts
AV-3000 FACEPIECES ONLY
figure 11
blAcK nose cup
behind face Seal
figure 12
grAy nose cup
in fronT of face Seal
blAcK
behind
fAce SeAl
grAy
in fronT of
fAce SeAl
AV-2000 STYLE FACEPIECES ONLY
Av-2000 nose cup
Always behind the face Seal
figure 13
9. Inspect the nose cup for cuts or damage. Also look for any signs
of damage to the facepiece port side of the nose cup where the
regulator attaches.
10. Check that the nose cup is
properly seated between the
flanges of the voicemitter
ducts. See FIGURE 10.
11. All SCOTT facepieces used with this respirator may be fitted with
a nose cup. Verify that the Nose Cup is properly installed for the
model of facepiece being used. A Nose Cup is standard on the
SCOTT AV-2000®, Weld-O-Vista, and AV-3000® full facepieces
and optional on the SCOTT-O-VISTA® full facepiece.
a) SCOTT AV-3000 and AV-3000 SureSeal Facepieces are avail-
able with two different styles of nose cup: a BLACK Nose Cup
which fits behind the face seal, and a GRAY Nose Cup which
fits in front of the face seal. The BLACK Nose cup must be fit-
ted BEHIND the Face Seal as shown in FIGURE 11. The GRAY
Nose Cup must be fitted IN FRONT OF the Face Seal as shown
in FIGURE 12.
b) The AV-2000, the Weld-O-Vista, and the SCOTT-O-VISTA, the
Nose Cup always goes BEHIND the face seal REGARDLESS
of the color of the nose cup. See FIGURE 13.
12. Verify that the facepiece is clean.
13. Adjust the head straps to the full outward position.
Proceed to
OPERATIONAL TESTING OF THE RESPIRATOR
.
WArning
To mAinTAin nioSh APProvAl, An Av-
3000 fAcePiece eQuiPPed WiTh A Sure-
SeAl fAceSeAl P/n 31001738 (SmAll),
P/n 31001739 (medium), or P/n 31001740
(lArge) muST be uSed
ONLY
WiTh
grey noSe cuP P/n 31001043 (SmAll),
P/n 31001044 (medium), or P/n 31001045
(lArge). uSe of A non-APProved con-
figurATion in A hAZArdouS ATmo-
SPhere mAy reSulT in SeriouS inJury
or deATh.