Repeat this action to change the Lock Level setting. The Lock Level setting can be
changed from any channel. If Lock Level 3 is set and any button is pressed, you are
prompted to enter the current Password. After the correct Password is entered, the
Lock Level setting is automatically changed to Level 0. If an incorrect Password is
entered, “bAd” is displayed at the front panel. For more information about Lock
Levels, see “
…
About Lock Levels”.
/2)UHTXHQF\
The LO (Local Oscillator) Frequency #1 option is an Alt-2 Mode function. The LO
Frequency #1 sets the satellite antenna LNB local oscillator #1 frequency, and is
valid only if the Frequency Mode is set to L-Band 1 (Lb1) or Downlink (dnLn). If
you are unsure about which Local Oscillator Frequency to use, contact your
dealer/reseller, or local service provider.
To display or change the LO Frequency #1
Perform the first step if you are changing the LO Frequency #1.
Step 1. If required, press 0 and then press SELECT to display the Installer Channel.
Step 2. Press ALT twice to change from normal operation to Alt-2 Mode.
The ALT LED is ON.
Step 3. Press 2 (LO 1) to display the current LO Frequency #1. Pressing the Ï/Ð arrow
button displays higher or lower frequency settings (frequencies are displayed
from 0 GHz through 15 GHz (see
About frequency settings). The default
setting is 9.750 GHz.
Step 4. When the desired setting is displayed at the front panel, press SELECT to
save the setting.
The front panel displays sav?.
Available options:
Press 1 to save the new setting (donE), or press 2 to discard all
changes (rstr), or press 3 to cancel the operation (abrt).
Repeat this action to change to another frequency. You can use the
Í
/
Î
arrow
buttons to change between low and high resolution. When displaying high resolu-
tion (i.e., least significant digits), the decimal point flashes ON and OFF repeatedly.
The Local Oscillator #1 frequency can be displayed from any channel, but can only
be changed from the Installer Channel (see “…About the current channel”). The
Local Oscillator #1 frequency is associated with the L-Band 1 [Lb1] Frequency
Mode, and must be lower than the Local Oscillator #2 frequency. For more infor-
mation about frequency settings, see “Setting up the receiver”.
/2)UHTXHQF\
The LO (Local Oscillator) Frequency #2 option is an Alt-2 Mode function. The LO
Frequency #2 sets the satellite antenna LNB Local Oscillator #2 frequency, and is
valid only if the Frequency Mode is set to L-Band 2 (Lb2) or Downlink (dnLn). If
you are unsure about which Local Oscillator Frequency to use, contact your
dealer/reseller, or local service provider.
To display or change the LO Frequency #1
Perform the first step if you are changing the LO Frequency #2.
Step 1. If required, press 0 and then press SELECT to display the Installer Channel.
Step 2. Press ALT twice to change from normal operation to Alt-2 Mode.
The ALT LED is ON.
Step 3. Press 5 (LO 2) to display the current LO Frequency #2. Pressing the Ï/Ð ar-
row button displays higher or lower frequency settings (frequencies are dis-
played from 0 GHz through 15 GHz (see
About frequency settings). The
default setting is 10.600 GHz.
Step 4. When the desired setting is displayed at the front panel, press SELECT to
save the setting.
The front panel displays sav?.
Available options:
Press 1 to save the new setting (donE), or press 2 to discard all
changes (rstr), or press 3 to cancel the operation (abrt).