Alarm Messages
4018055 Rev B
63
System Errors
The following table contains the System errors.
Alarm/Reference/Detail Description
Alarm: Qam Card <X>:
Vcobaud
Ref: Baud VCO not locked
Detail: - - - -
The Baud VCO of the QAM card in question is not locked. The board
should be left for at least 1 minute to see if the error clears. If after 1
minute the alarm still persists then the card should be removed and
re-inserted again. If this action does not clear the alarm then a
Scientific Atlanta representative should be contacted. The alarm clears
when the VCO locks.
<X> represents the QAM card number.
Alarm: Qam Card <X>:
VCO2
Ref: VCO2 Output <Y>
Unlock
Detail: - - - -
The VCO 2 of the QAM card in question is unlocked. The board
should be left for at least 1 minute to see if the error clears. If after 1
minute the alarm still persists then the card should be removed and
re-inserted again. If this action does not clear the alarm then a
Scientific Atlanta representative should be contacted. The alarm clears
when the VCO locks.
<X> represents the QAM card number and <Y> the RF output
number.