Chapter 5 Viewing Alarm Messages
Alarm/Reference/Detail Description
Alarm: Qam Card <X>:
Calibration
Ref: Calibration file error
Detail: (see description)
The calibration data on the QAM card in question became corrupt. A
Scientific Atlanta representative should be contacted.
<X> represents the card number. The detail will indicate the I2c error
that has been detected.
Alarm: Qam Card <X>:
Oven <Y>
Ref: Oven Temperature
Detail: - - - -
The temperature of the modulator stabilization circuit is out of
specification. The board should be left for at least 1 minute to see if the
error clears. If after 1 minute the alarm still persists then the card
should be removed and re-inserted again. If this action does not clear
the alarm then a Scientific Atlanta representative should be contacted.
This alarm clears when the communication is established with the
device.
<X> represents the QAM card position and <Y> the RF Output
number.
Alarm: Rear Panel Fan <X>
Ref: Fan malfunction
Detail: Rear panel fan <X>
failed
The indicated fan has stopped working. Check the fans. When the
fans are working again the alarm clears.
<X> represents the fan number.
56
4018055 Rev B
Summary of Contents for Continuum DVP eXtra Dense QAM Array 24
Page 1: ...4018055 Rev B Continuum DVP eXtra Dense QAM Array 24 Configuration Guide...
Page 2: ......
Page 4: ...For Your Safety iv 4018055 Rev B...
Page 6: ......
Page 10: ......
Page 12: ......
Page 14: ......
Page 24: ......
Page 32: ......
Page 44: ...Chapter 3 Configuring the XDQA24 System 30 4018055 Rev B...
Page 64: ......
Page 88: ......
Page 96: ......
Page 103: ......