Maintenance
36
09.00 | PWG-plus | Assembly and operating manual | en | 389495
7.3 Lubricants/Lubrication points
SCHUNK recommends the lubricants listed.
During maintenance, treat all greased areas with lubricant. Thinly
apply lubricant with a lint-free cloth.
Lubricant point
Lubricant
Metallic sliding surfaces
microGLEIT GP 303
All seals
Renolit HLT 2
Bore hole at the piston
Renolit HLT 2
Depending on the load, the guides in the housing can be re-
lubricated.
7.4 Disassemble the product
7.4.1 Variant without maintenance of gripping force
Position of the item numbers:
Ø
Remove compressed air lines.
Ø
Remove the cover (6).
Ø
Unscrew and remove the screws (41) and remove the cover (8).
Ø
Unscrew screw (40) and remove cylinder piston (60) from the
housing (1).
Ø
Loosen set-screws (21) in the base jaws (2).
Ø
Remove the bolt (5).
Ø
Pull the base jaws (2) out of the housing (1).
Ø
Push the piston assembly (3, 4 and 39) upwards out of the
housing (1).