Maintenance
09.00 | PWG-plus | Assembly and operating manual | en | 389495
41
7.5.2 Variant with maintenance of gripping force "O.D. gripping"
PWG-plus 50-100
101
102
25
45
31
30
9
Dimensions of assembly device in chapter
cylinder piston with gripping force maintenance
Ø
Mount the base jaws (2) and piston (3) with the seal (31) in the
housing (1).
Ø
Insert the compression spring (25) and the cylinder piston (9)
with the seal (30) into the housing (1).
Ø
Carefully pull the device (101) over the cylinder piston (9) and
mount onto the housing (1) with the screws (102).
Ø
Tighten the screw (45).
✓
Observe the maximum tightening torque,
Ø
Remove the device (101).
Ø
Reassemble the product. Assembly is done in the reverse order
of disassembly,
46].