5.2.2 IN 40 / IN 80 inductive proximity switch
Assembly of IN 40
PGW-plus 50-160
mounting kit
1
2
3
4
5
6
7
Ø
Fasten angle (2) to housing using screws (1).
Ø
Fasten bracket (3) to the angle (2) using screws (4).
Ø
Fasten the control cams (5) to the rotary bolt using the screws
(6) place lock washers (7) between control cams and screw
head.
Assembly of IN 40
PGW-plus 200-240
mounting kit
Ø
Fasten bracket (1) to the housing using screws (2).
Ø
Fasten the control cams (3) to the rotary bolt using screws (5)
place lock washers (4) between control cams and screw head.