Assembly
32
09.00 | PWG-plus | Assembly and operating manual | en | 389495
Ø
Press the Teach-button (4) for 5 seconds.
✓
LED 1 (3) will flash up after 2 seconds.
✓
LED 1 will stop after 5 seconds.
Ø
Release the Teach-button.
Ø
Move the gripper to the "switch-off point for switching point 1"
position.
Ø
Press the Teach-Button (4) briefly.LED 1 (3) will light up twice.
Ø
Move the gripper to the "switch-off point for switching point 2"
position.
Ø
Press the Teach-Button (4) briefly.
✓
LED 2 (5) will light up twice.
✔
The mounting of the sensor MMS-P is completed.