![SCHUNK LDT Series Assembly And Operating Manual Download Page 98](http://html1.mh-extra.com/html/schunk/ldt-series/ldt-series_assembly-and-operating-manual_1215944098.webp)
Technical Data
96
05.00 | LDT | Montage- und Betriebsanleitung | en | GAS360927
3 Technical Data
Construction size
LDT-xS-0100
LDT-xS-0200
LDT-xS-0300
LDT-xL-0200
Max. stroke [mm]
2800
2700
2800
2700
Nominal strengh [N] */**
130
210
330
230
Maximum strengh [N]
250
500
750
500
Repeatability [mm]
±0,01
±0,01
±0,01
±0,01
Max. standstill current [A eff]
2,24
3,62
4,02
3,97
Maximum current [A eff]
7,5
15
14
15
Winding resistance at
25°C Z [Ohm]
7,6
3,8
4,4
3,8
Construction size
LDT-xL-0400
LDT-xL-0600
LDT-DL-0800
LDT-DL-1200
Max. stroke [mm]
2800
2700
2800
2700
Nominal strengh [N] */**
350
500
on request
800
Maximum strengh [N]
1000
1500
on request
3000
Repeatability [mm]
±0,01
±0,01
±0,01
±0,01
Max. standstill current [A eff]
6,03
6,1
on request
9,76
Maximum current [A eff]
30
28
on request
56
Winding resistance at
25°C Z [Ohm]
1,9
2,2
on request
1,1
Max. intermediate circuit
voltage [V]
750
Ambient temperature
max. [°C]
40
Ambient temperature
min. [°C]
5
Surface temperature [°]
70
Impermeability IP
00
Pressurising medium:
compressed air - quality
ISO 8573-1:7 4 4
Pressurising medium:
compressed air min/max
[bar]
5-7
Noise emission [dB(A)]
≤ 70
* At installation altitudes over 1000 m above sea level, the
performance data reduce
** Depending on the installation situation (heat dissipation) and at
20°C ambient temperature.