![SCHUNK LDT Series Assembly And Operating Manual Download Page 124](http://html1.mh-extra.com/html/schunk/ldt-series/ldt-series_assembly-and-operating-manual_1215944124.webp)
Maintenance and repair work
122
05.00 | LDT | Montage- und Betriebsanleitung | en | GAS360927
7.3 Turning the motor plug
Turning the motor plug
1
Motor plug
Removing the motor
plug
Turning the motor plug
Ø
Uninstalling the motor housing
Ø
Unscrew the 2 screws (1).
Ø
Remove the cable cover (2).
Ø
Unscrew the 4 screws (3).
Ø
Carefully pull out the power connector (4) by about 2 mm.
Installing the motor
plug
Ø
Carefully press the power connector (4) into the notch.
Ø
Screw in the 4 screws (3).
Ø
Lay the cable parallel into the slot.
Ø
Fit the cable cover (2).
Ø
Screw in the 2 screws (1).
Ø
Install the motor housing.