![SCHUNK LDT Series Assembly And Operating Manual Download Page 138](http://html1.mh-extra.com/html/schunk/ldt-series/ldt-series_assembly-and-operating-manual_1215944138.webp)
Maintenance and repair work
136
05.00 | LDT | Montage- und Betriebsanleitung | en | GAS360927
7.12 Limit switches and reference switches
Mechanical limit switches and inductive reference switch
1
Limit switches, mechanical 2
Reference switch, inductive
3
Switching lug
4
Limit and reference switch
baseplate
5
Limit switch baseplate
6
Distance plate
7
Switching distance,
mechanical limit switch
8
Switching distance,
inductive reference switch
Ø
Unscrew the mounting screws of the switch baseplate (4/5).
Ø
Unscrew the mounting screws of the switch (1/2) and remove
the switch.
Ø
Install the new switch and adjust the switching distance (7/8).
Ø
Fit the switch (1/2) and baseplate (4/5)
Ø
Perform a test run.