![SCHUNK LDT Series Assembly And Operating Manual Download Page 115](http://html1.mh-extra.com/html/schunk/ldt-series/ldt-series_assembly-and-operating-manual_1215944115.webp)
Assembly
05.00 | LDT | Montage- und Betriebsanleitung | en | GAS360927
113
6.2.6 TTK70 absolute measuring system
Description
TTK70
Operating voltage [VDC]
7 - 12
Ausgangssignal
Hiperface, Sin, Cos
Signal amplitude [Vss]
1 ± 10 %
Offset sine/cosine [V]
2.5 ± 0.5 %
Signal period [µm]
1000
Distance between reading head and
measuring tape [mm]
0.1 - 0.2
Pin
Assignment
1
SIN-
2
SIN+
3
COS-
4
COS+
5
Enc data+
6
Enc data-
7
GND
8
VCC encoder