56
Code 93
Return to Default
After read this setting, the parameters of Code 93 will be returned to factory
default.
Return Code 93 to Default
Enable/Disable Code 93
Enable Code 93 Disable Code 93
Code ID
Read “Enable CodeID
”
to start the setting, then scan the corresponding 16 HEX
Value of CodeID character and save.
Code 93 - Enable CODEID
Set the CodeID of Code 93 as
“
p
”(
16 HEX Value is 0x70
):
1. Read above “Enable CodeID”
2. Read number
“
7
”
,
“
0
”
(See Appendix- Data Code)
3. Read “Save”
Check
Code 93 not limit to include the check digit, if there is check digit, the last
character will be. Check digit is the counted value according to all the data, which used
to check the correctness of the data.
If check digit is “None”, the scanner will transfer the code data normally.