55
Start and End Character
Disable Start and End Character Enable Start and End Character
ABCD/ABCD As Start and End Character ABCD/TN*E As Start and End Character
abcd/abcd As Start and End Character abcd/tn*e As Start and End Character
Code Length Limit
The scanner can only read the the code length within the limited of Codabar, the
limit is from the minimum to maximum value (including the minimum and maximum
value), the unit is character. If the length of Codabar is out of the limit, the scanner will
not be able to read or transmit the code.
Read “Minimum Length” to set the minimum length of code.
Read “Maximum Length” to set maximum length of code.
Codabar Maximum Length Codabar Minimum Length
The maximum length value of any type of 1D code is not more than 255. If the
maximum length is shorter than the minimum length, the scanner can only read this
two length of code; if the maximum length is equal to minimum length, the scanner can
only read the code of this length.
This length is the length of the code itself, not including prefix/suffix, tailed suffix,
AIM-ID,CODEID.