SATEL INTEGRA
Plus
61
Do not arm if reporting trouble
[If monit.trbl.] – if this option is enabled, arming will be
impossible in case of any problems with reporting.
The options D
O NOT ARM IF TAMPERED
, D
O NOT ARM IF BATTERY TROUBLE
, D
O NOT ARM IF
TROUBLE
, D
O NOT ARM IF OUTPUTS TROUBLE
and D
O NOT ARM IF REPORTING TROUBLE
are
available, when the W
ARN WHILE ARMING IF TROUBLE
option is enabled.
5.5 Times
Global entry delay
– parameter taken into account in the delayed zones, for which the
programmed E
NTRY DELAY
is equal to 0.
Global alarm time
– time of signaling alarm in keypads, proximity card arm/disarm devices,
proximity card readers and DALLAS chip readers.
No armed indication after
– time counted from the moment of partition arming, during which
information about armed status is displayed on the keypads.
Default partition block time
– the time period during which the W
ITH TEMPORARY BLOCK
type
partitions with enabled D
EFAULT BLOCK TIME
option will be blocked.
AC loss report delay
– time during which the control panel must not receive AC power so
that information of it can be saved to the event log. Having programmed the value 0
means that the information of AC power loss will not be saved to the event log.
Telephone line loss report delay
– time during which abnormal voltage must be on the
telephone line for the control panel to report the telephone line trouble. A delay in reporting
the trouble prevents sending information about short-time voltage dips (e.g. during a
phone call) or decays.
5.6 Service options and parameters
In the keypad the options are available in SM
SETTINGS
submenu.
Disable service mode
[Block SM] – with this option enabled, entering the service mode
"from pins" (by hardware means) will be impossible (entering the service mode "from pins"
will only be possible if the control panel factory settings are restored).
Disable downloading
[Block DWNL] – with this option enabled, starting communication with
the D
LOAD
X program "from pins" will be impossible.
Hide service mode after
[Hide SM after] – the time counted from the last operation
performed in the service menu, after expiry of which the service mode menu will be hidden
(see: p. 5). If value 0 is programmed, the automatic hiding of the service mode will be
disabled.
Service mode beep
[SM sounds] – with this option enabled, the service mode will be
acoustically signaled in the keypad.
5.7 Other parameters
Rings before answer
[Rings to answer] – number of rings after which the control panel will
go off hook.
User code min. length
[Min. code length] – the minimum required number of digits in the
user code. The parameter will be taken into account when creating and editing the codes
(but it has no effect on the codes already existing in the system).
Prefix length
– the required number of digits in the prefix. Entering a number different from 0
means that from now each code will have to be preceded by a prefix:
–
normal
– for everyday use. By default, it consists of a suitable number of digits 0 (e.g. if
the prefix length has been set at 4, the default prefix will be: 0000);