SATEL INTEGRA
Plus
27
2. Connection initialized from the D
LOAD
X program, but the control panel calls back and sets
up the connection (built-in 300 bps modem or external analog modem). The control panel
may only be remotely programmed from a specified locality.
3. Connection initialized by means of SMS (SATEL GSM module operating as an external
modem).
4. Connection initialized by the control panel (all configurations). The control panel may only
be remotely programmed from a specified locality. It can be applied if the system user
prefers that the remote programming cannot be carried out without his knowledge.
Configuring the control panel
If the connection is to be realized by the control panel, program the telephone number of
the computer with D
LOAD
X program installed.
If an external modem is connected to the control panel, enable the E
XTERNAL MODEM
option.
If a GSM or ISDN modem is connected to the control panel, enable the M
ODEM
ISDN/GSM/ETHM
option.
If the connection is to be initialized by the computer:
– enable the A
NSWERING
–
MODEM
option
(any modem) or the A
NSWERING
–
ETHM/GSM
option (recommended for GSM or ISDN modem);
– define the number of rings after which the control panel will answer the connection (this
does not apply to the external GSM or ISDN modem);
– enable the D
OUBLE CALL
option if the control panel is to answer the connection only after
the second call (this does not apply to the external GSM or ISDN modem).
The above-mentioned parameters and options can be programmed:
– using the keypad, in the service mode (SM
SETTINGS
and O
PTIONS
submenu);
– using the D
LOAD
X program during local programming ("Identifiers and tel. no" and
"Options" windows).
Configuring the modem connected to computer
Click on the
button. The "Configuration" window will open. The "Modem" tab allows you
to define three modem configurations:
1. analog modem for communication with the built-in modem of the control panel;
2. analog modem for communication with the external modem of the control panel;
3. ISDN or GSM modem for communication with the ISDN or GSM modem of the control
panel.
Clicking on the
button will allow you to edit the parameters of the port for modem
communication, as well as the initializing commands for the selected configuration.
Connection initialized from the
D
LOAD
X
program
The telephone number of the alarm control panel must be programmed in the D
LOAD
X
program ("Identifiers and tel. no" window).
1. Click on the
button in the D
LOAD
X program.
2. A drop-down menu will be displayed. Select in it the appropriate control panel modem.
A window will open in which information on the modem initialization will be displayed.
3. Click on the “Connect” button.