26 Programming
SATEL
To start the local programming function you can use the [service code]
01 key
shortcut.
6. Establishing communication will be signaled on the monitor screen by a corresponding
message.
2.2.4 Starting local programming "from pins"
If the control panel does not support LCD keypads, does not accept the service code, etc.,
you can use the emergency procedure of, so-called, starting "from pins." The control panel
RS-232 port must be connected to the computer (the USB port cannot be used for the
emergency starting procedure). In the D
LOAD
X program, indicate the computer port to which
the control panel is connected. Then, follow the procedure described in section S
TARTING THE
SERVICE MODE
"
FROM PINS
Running the local programming "from pins" is not possible, if the D
ISABLE
D
OWNLOADING
option is enabled.
2.2.5 Finishing local programming
To end the local programming you can use the E
ND
DWNL-RS function ([
service code
]
DOWNLOADING
E
ND
DWNL-RS).
The local programming function will be finished automatically after 255 minutes have elapsed
since the last use of the D
LOAD
X program, and the service access was blocked or expired
during that time.
The local programming function must be disabled, if the control panel is to
communicate through the RS-232 port with an external analog modem, GSM module
or ETHM-1 module (e.g. during remote programming, event reporting, etc.).
2.2.6 Starting remote programming via modem
The control panel has a built-in 300 bps modem. It can also operate in conjunction with
external modems. For information on how to connect the external modem to the control panel
please refer to the I
NSTALLER MANUAL
. Initializing the modem connection is possible, if there is
a properly matched modem on the computer side (see Table 4).
Configuration on control panel side
Configuration on computer side
Built-in 300 bps modem
Analog modem
Analog modem
External analog modem
GSM modem
ISDN modem
External ISDN modem
GSM modem
Analog modem
External GSM modem
GSM modem
Table 4. Selecting control panel and computer modems.
Communication can be established in several ways (shown in parentheses is information on
the required configuration on the control panel side):
1. Connection initialized from the D
LOAD
X program (built-in modem 300 bps or external
analog modem). This method makes it possible to establish connection with the control
panel from any location. Establishing connection by this method is possible, if the
computer telephone number has not been programmed in the control panel.