Check the Final Drive Oil Level
1. Park the machine on a flat, level surface, positioning
the oil drain plug (2) on the final drive cover at the
bottom and the oil level mark parallel with the ground.
2. Prepare the machine for service. See “Maintenance
3. Remove any dirt from around the oil level check plug
(1).
4. Slowly loosen the oil level check plug to relieve
pressure within the final drive.
5. Remove the oil level check plug and make sure that the
oil level is within 0.4 in. (10 mm) of the bottom of the
plug hole.
6. Add oil through the oil level check plug hole as necessary until the level is within 0.4 in. (10 mm) of the bottom
of the plug hole.
7. Replace the O-ring on the oil level check plug.
8. Install the oil level check plug.
9. Repeat steps 3 through 8 for the opposite final drive.
CAUTION!
•
Allow the final drive to cool before servicing. Hot oil may cause burns or other serious
injury.
•
Wear safety goggles, gloves, and other personal protective equipment (PPE) to prevent
serious injury.
•
The final drive oil may be under pressure. Remove the plugs slowly to prevent injury.
Failure to follow these precautions could result in injury.