Fuel
Observe the following when adding fuel:
•
Use #2 diesel fuel or a mixture of #2 diesel and #1 diesel fuels in cold weather climates.
•
Use only ultra-low sulfur fuel with a limit of S.15 ppm (S.15 PPM) for all normal operations.
•
SANY does not recommend the use of any diesel fuel with a cetane level less than 40.
•
Do not use gasoline, kerosene, or any unapproved fuels in the fuel system.
•
If fuel waxing or bacterial growth occurs in the fuel system, contact a SANY dealer.
•
Make sure there is no water or foreign material in the fuel. Take appropriate precautions to prevent fuel
contamination during refueling.
Engine Coolant
Engine coolant is an important fluid, protecting the engine against overheating and freezing.
•
If using concentrated engine coolant, use distilled water to dilute per instructions on the engine coolant
container. Natural water contains large amounts of minerals which can form scale in the engine and
radiator. Mineral scale is not easily removed and can cause overheating.
•
Precautions in this manual must be followed when working with engine coolants.
•
Some engine coolants are flammable. Keep them away from open fire.
•
If the engine is overheating, wait for the engine to cool before refilling engine coolant.
WARNING!
• Fuel or fuel vapors that come into contact with hot surfaces or electrical components can
cause a fire.
• Never service the fuel system near an open flame or while smoking.
• Clean up spilled fuel immediately.
Failure to follow these warnings could result in death or serious injury.
NOTICE!
Never dilute fuels. Damage to the injection system can result, causing the machine to operate
improperly.