SY265C LC/SY265C LR Excavator OMM
SANY
Operation and Maintenance Manual — 0420
5-71
TABL
E OF
CONT
E
N
TS
INTRODUCTION
SAFE
T
Y
MACHIN
E
CONTROLS
MACHINE
OP
ERA
T
IO
N
MA
INTENANCE
SPEC
IFI
CA
TIO
N
S
OP
T
IO
N
A
L
EQUI
PMENT
Replace the Hydraulic Pilot Filter Element
1. Prepare the machine for service. See “Maintenance
2. Relieve hydraulic system pressure. See “Relieve
Hydraulic System Pressure” on page 5-67.
3. Open the right rear door and locate the hydraulic pilot
filter housing (1) behind the hydraulic oil filter.
4. Place an appropriately sized container under the pilot
filter housing to catch leaking hydraulic oil.
5. Remove the pilot filter bowl (2).
WARNING!
• Allow the hydraulic system to cool before servicing. Hot oil may cause burns or other
serious injury.
• The hydraulic tank may be under pressure, and hydraulic oil may be present at the filler cap.
Relieve any pressure to prevent injury.
Failure to follow this warning could result in death or serious injury.
NOTICE!
Dispose of drained hydraulic oil in accordance
with local environmental regulations. Failure to
do so could damage the environment.
Fig. 5-89
1
0005320
2
Summary of Contents for SY265C LC