SY265C LC/SY265C LR Excavator OMM
5-60
Operation and Maintenance Manual — 0420
SANY
Electrical System
Check the Backup Camera
1. Turn the key switch to the ON position.
2. Push button F4 on the monitor to activate the backup
camera (1) and view activity behind the machine.
3. Make sure the backup camera is operating correctly
and is free of all obstructions.
Disconnect the Electrical Power
1. Prepare the machine for checks and inspections. See
“Maintenance Safety” on page 2-8.
2. The batteries are behind the left rear access door. See
“Left Access Doors” on page 4-10.
3. Allow several minutes for any accumulated battery
gases to clear before servicing the batteries.
4. Turn the battery disconnect switch to the OFF position.
See “Battery Disconnect Switch” on page 3-20.
5. Remove the fasteners (2) and remove the battery
cover (1).
WARNING!
When working with any open electrical power source, make sure that your hands are free of
any metal objects (rings, watches, jewelry, etc.) that could come in contact with electrical
power points. Failure to avoid this hazardous situation could result in death or serious injury.
Fig. 5-70
1
Fig. 5-71
1
2
Summary of Contents for SY265C LC