7
2.3 PRODUCT SPECIFICATION
Individual Specification
■220V Signal phase
Series
Model number S900-2s
□□□
G
0.2
0.4
0.75
1.5
2.2
O
ut
put
Max applicable motor output
power(kW)
0.2
0.4
0.75
1.5
2.2
Max applicable motor output
power(HP)
0.25
0.5
1
2
3
Output rated capacity(kVA)
0.6
1.0
1.9
2.5
4.2
Output rated current (A)
1.6
2.5
4.2
7.5
11
Output frequency range
0.1~400Hz
Over load capacity
150% of rated output current and run for 60sec.
Max output voltage
Correspond to input power supply
Input
Phase number. Voltage. Frequency
Single phase. 200 to 240V. 50/60Hz
Allowable variation range for Voltage.
Frequency
Voltage: ±10%, Frequency: ±5%
Input current (A)
4.9
6.5
10
17.5
27
Cooling System
Natural
air cooling
Forced air cooling
■440V Three phase Series
Model number S900-4T
□□□
G
0.4
0.75
1.5
2.5
3.7
O
ut
put
Max applicable motor output
power(kW)
0.4
0.75
1.5
2.5
3.7
Max applicable motor output
power(HP)
0.5
1
2
3
5
Output rated capacity(kVA)
1.2
2.3
3.2
4.2
6.3
Output rated current (A)
1.5
2.5
4.2
5.5
8.2
Output frequency range
0.1~400Hz
Over load capacity
150% of rated output current and run for 60sec.
Max output voltage
Correspond to input power supply
Input
Phase number. Voltage. Frequency
Three phase. 380 to 460V. 50/60Hz
Allowable variation range for Voltage.
Frequency
Voltage: ±10%, Frequency: ±5%
Input current (A)
1.9
3.5
6.0
7.2
9.0
Cooling System
Natural
air cooling
Forced air cooling