52
5-07~5-14
Reserved
5-15
Auto programming operation mode
Factory setting
d 0
Setting
range
d 0
Auto operation mode cancelled
d 1
Stop after auto operating for 1 cycle.
d 2
Auto operation perform in cycles
d 3
Stop after auto operating for 1 cycle (STOP intervals).
d 4
Stop after auto operating for 1 cycle (STOP intervals).
This parameter shall be applicable for operation process control of general micro machine, food
treatment machine and washing machine, and some control wiring such as traditional relay,
switch and timing machine shall be replaced; when this function is used, many parameters shall
be set, and attention shall be paid to each detail. Read descriptions below carefully.
5-16
PLC Rotating Direction 1 (0 to 7th step speed)
Factory setting
d 0
Setting range
d 0<-> d 255
(0: forward run; 1: reverse run)
Unit
1
This parameter determines rotating direction of programming operation 5-00 to 5-06 as well as all
step running of the master speed.
Setting method: Operation direction setting is in binary 8 bit, and only input this parameter after it
is transferred into decimal value.
5-17
Reserved
MASTER SPEED
FREQUENCY
time