40
2-06
External fault (EF ) stop mode setting
Factory setting
d 1
Setting
range
d 0
Reserved
d 1
EF free running to stop
Description of action: When EF is detected by the system, a stop signal shall be sent and AC motor
shall stop in the mode of this parameter.
2-07
External fault (EF ) stop mode setting
Factory setting
d 2
Setting
range
d 0
AVI Zeroing braking to stop
d 1
AVI Zeroing free running to stop
d 2
AVI Zeroing braking to stop and running signals are reserved.
Description of action: A stop signal shall be sent when frequency is set to AVI, parameter is set to 0
or 1 and system has detected that AVI set frequency is 0, AC motor drive shall coast to a stop in
accordance with this setting at the same time; if this parameter is set to 2 and AVI set frequency is 0,
motor stops by braking, but running signals are reserved. Motor shall run continuously when AVI set
frequency rise up again.
Notes: Operation key shall be unavailable when parameter is set to 0 or 1 and AVI input is 0.
2-08
Reserved
Factory setting
d 0
2-09
PWM load wave frequency option
Factory setting
d 6.0
Setting range
d 2.0<->d 12.0kHz
Unit
0.1kHz
Load frequency of PMW output shall be set by this parameter.
Load frequency
Electromagnetic
noise
Noise, spill current
Radiation
2kHz
Big
│
Small
Small
│
Big
Small
│
Big
6kHz
12kHz
The above form suggests that load wave frequency shall influence electromagnetic noise, radiation
as well as interference to the environment of motor; thus, decreasing the load wave frequency shall
help the motor drive to decrease temperature rise if ambient noise exceeds noise of the motor; in
case of high load wave frequency, although operation noise shall be eliminated to a large degree,
attention shall be paid to the interference and protection of the machine.
2-10
Operation direction inhibition setting
Factory setting
d 0
Setting range
d 0
0: Fwd/rev run available
d 1
1: Reverse run inhibited
d 2
2: Fwd run inhibited
If parameter is set to 1” Reverse run inhibited”, REV reference of both the operator and external
terminals shall be unavailable. Even if Rev Run is performed currently, it shall be switched to fwd
run directly. Also, provided that fwd run is inhibited, only Rev run reference shall be performed.