30
9 Communication Parameters
Set during running available
Parameter
Parameter functions
Setting range
Factory setting
9-00
Communication address
1~247
1
9-01
Communication transmitting speed
0:Baud rate 4800
1
1: Baud rate 9600
2:Baud rate 14400
3: Baud rate 19200
4: Baud rate 38400
9-02
Transmitting fault treatment
0:Warning and running continuously
0
1:warning and deceleration to stop
2:warning and coasting to a stop
3:no warning and running continuously
9-03
Communication watchdog
Time setting
0: Not detected
0
1~20s
9-04
Communication Material Format 1
ASCII mode
0:8, N,1
0
1:8, N,2
2:8, E,1
3:8, E,2
4:8, O,1
5:8, O,2
Communication Material Format 1
RTU mode
6:8, N,2
7:8, E,1
8:8, O,1
9~11 Reserved
9-05
Reserved
9-06
Reserved
9-07
Communication response delay time 0~200 (one unit=2ms)
1