33
4.23 Set up I/O Status And Time Interval
Use this message to define each I/O should be NC(normal close) or NO(normal) and the reply time interval while the
status is triggered.
Command format: #
「
Username
」
,
「
Password
」
,
「
I/O 1/2/3/4/5/6
」
,
「
NC/NO
」
,
「
Interval(seconds)
」
,
「
Total number of report
」
,
「
Delay time
」
*
Example: #username,0000,io1,NC,60,3,5*
Table 4.23.1 The explanation of each segment.
Table 4.23.2 The reply when the setting successes
Text Keyed In SMS
Description
# Start
sign.
username
*Default ID of GC-101.
*If you have changed the Username, please use the updated one.
0000
*Default password.
*If you have changed the password, please use the updated one.
io1
Setting up io1’s status
NC/ NO
NC: The I/O will be triggered when the status is normal close
NO: The I/O will be triggered when the status is normal open
60
A constant interval of sending data
3
The amount of 3 messages sent automatically
5
Delay time. It means how much time the I/O will start to detect after the I/O
status is set up. In this case, the I/O will start to detect after 5 seconds when
its status is set up.
* End
sign.
Situation
Message Reply
Success
Username, setup ok. Device I/O (1-6) settings is updated