34
4.24 Activate or Deactivate I/O Output And Active Time
Use this message to control external alarm sensor is activated or deactivated and its active time. For instance, if a buzzer
is connected to output and set when the door detection is trigger, buzzer will make “bee” sounds constantly for 10 seconds,
while the door detection is triggered, GX-101 will send the SMS to the user and the buzzer will make “bee” sound for 10
seconds. Instead, if the buzzer is not connected to output port, GX-101 will send SMS to user only.
Command format: #
「
Username
」
,
「
Password
」
,
「
O1/ O2
」
,
「
1
」
,
「
Active time(seconds)
」
*
Example: #username,0000,o1,1,20
To deactivate the output
Command format: #
「
Username
」
,
「
Password
」
,
「
O1/ O2
」
,
「
0
」
*
Example: #username,0000,o1,0,*
Table 4.24.1 The explanation of each segment.
Table 4.24.2 The reply when the setting successes
Text Keyed In SMS
Description
# Start
sign.
username
*Default ID of GC-101.
*If you have changed the Username, please use the updated one.
0000
*Default password.
*If you have changed the password, please use the updated one.
o1
Setting up o1’s status. Please note o1 controls I/O 1-3; o2 controls I/O 4-6
1
0: deactivate output; 1: activate output
20
Output sensor active time
* End
sign.
Situation
Message Reply
Success(activate)
Username, setup ok. Device I/O output(1-3) is switched on
Username, setup ok. Device I/O output(4-6) is switched on
Success(deactivate)
Username, setup ok. Device I/O output(1-3) is switched off
Username, setup ok. Device I/O output(4-6) is switched off