2012 LED Factory Test Mode (ES9000)
Main Board Patterns Test
Select:
EchoP Pattern Sel
T-CON Patterns Test
Select:
T-CON Test Pattern
Test Procedure:
1. With TV Power On…
“Mute/147/Mute”
for a
Main
Board
Test Pattern
&
“
Mute/369/Mute”
for a
T-CON
Board
Test Pattern
2. Access
Factory Mode
Standby: Mute,182,power
Power On: Info, Factory
& Select
SVC
3. Select
Test Pattern
4. Select
EchoP Pattern Set
Use the right arrow key to
Scroll through patterns
5. Select
SOC T-CON Test Pattern
or
Echo-FP Post Test Pattern
Use the right arrow key to
scroll through the patterns.
•
If
T-CON
is
OK and
EchoP
(Main Board) is OK the problem is normally the source or input
•
If
T-CON
is OK and
EchoP
(Main Board) is not OK, problem is the LVDS Cable or Main Board.
•
If
T-CON
or
Echo-FP Post Test Pattern
is not OK then the problem is the T-CON Board or PANEL