2012 LED Factory Test Mode (ES9000)
Main Board Patterns Test
Select:
EchoP Pattern Sel
T-CON Patterns Test
Select:
T-CON Test Pattern
Test Procedure:
1.
Access
Factory Mode
Standby: Mute,182,power
Power On: Info, Factory
& Select
SVC
2.
Select
Test Pattern
3.
Select
EchoP Pattern Set
Use the right arrow key to
Scroll through patterns
4.Select
SOC T-CON Test Pattern
or
Echo-FP Post Test Pattern
Use the right arrow key to
scroll through the patterns.
•
If
T-CON
is
OK and
EchoP
is OK the problem is normally the source or input
•
If
T-CON
is OK and
EchoP
is not OK, problem is the LVDS Cable or Main Board.
•
If
T-CON
or
Echo-FP Post Test Pattern
is not OK then the problem is the T-CON Board or PANEL
Summary of Contents for UN75ES9000F