4. Troubleshooting
► Error Code
C3–1110
► Error message
Prepare new imaging unit.
► Symptom
Imaging unit has almost reached the end of its life.
► Troubleshooting method
1) Prepare the new imaging unit because it will be exhausted soon.
► Error Code
C3–1140
C3–1150
C3–1170
► Error message
End of life, Replace with new imaging unit.
Replace with new imaging unit
End of life, Replace with new imaging unit.
► Symptom
Imaging unit is at the end of its life.
► Troubleshooting method
1) Open the front cover and side cover.
2) Remove the toner cartridge.
3) Remove the imaging unit and replace it with new one.
4) Install the toner cartridge.
5) Close the side cover and front cover.
► Error Code
C3–1210
► Error message
Imaging Unit Failure:#C3-1210. Please turn off then on.
► Symptom
Sensor calibration error that detects the toner density for image stabilization control has occurred.
► Troubleshooting method
1) Open the front cover and side cover.
2) Remove the toner cartridge.
3) Remove and reinstall the imaging unit.
4) Install the toner cartridge.
5) Close the side cover and front cover.
6) If the problem persists, replace the imaging unit.
4-98