4. Troubleshooting
4.5.5.2. Fax Diagnostics
Fax NVM Read/Write
•
Diagnostics > Fax Diagnostics Fax NVM Read/Write
Purpose
To change a configuration value for fax firmware.
Operation Procedure
When the main “NVM Read/Write” window displays, users can navigate through the list of
configuration values that display along with description.
Users can also input a code to the text box to find a configuration value directly.
After selecting one value, pressing “Edit” button will open an interface for user input.
Verification
N/A
Specification
N/A
Reference
N/A
Code
NVM Name
NVM Description
Default
20-200
Pause Dial Time
Pause Time (value * 1000ms)
Country
Value
20-210
Dial Pulse M/B ratio
33 / 66 40 / 60
Country
Value
20-220
Auto Dial Start Pause Time
Pause time before auto-dialing (second)
1
20-300
Ring On Time
Ring On Time (ms)
170
20-310
Ring Off Time
Ring Off Time (ms)
560
20-320
Ring Detection Freq
sets the Call Indication frequency range that
will be detected by LIU
1
20-330
Ring On Max Time
Ring On Max Time (ms)
5100
20-340
Ring Off Max Time
Ring Off Max Time (ms)
11100
20-400
DTMF High-Freq Level
DTMF High-Freq. Level (dBm)
Country
Value
20-410
DTMF Low-Freq Level
DTMF Low-Freq. Level (dBm)
Country
Value
20-420
DTMF Timing
DTMF duration of on/off output ( Ms)
8
20-500
Dial Mode
Select Tone / Pulse
Country
Value
20-520
Error Rate
Adjust Error Rate ( Off / 5% / 10% / 20% )
2
20-530
Dial Tone Detect
detect dial tone prior to sending
Country
Value
20-540
Loop Current Detect
detect if loop current is present prior to sending
Country
Value
20-550
Busy Signal Detect
detect busy signal to allow redials
Country
Value
20-560
TCF Duration
Adjust TCF duration (ms)
1500
20-800
Modem Speed
Select Modem Start Speed
24
20-810
Fax Transmission Level
Adjust Fax Transmission Level (dBm)
Country
Value
20-830
Auto Dial Timeout
Adjust Auto Dial Timeout (second)
Country
Value
4-52