4) Optional function
SW02
SW01
Cool
Heat
Auto
DIP SW
Description
K1
K2
Restriction setting on wired/wireless remote control use
0''
0''
Wired/Wireless remote control use is allowed all the time. Level 0
ON
0''
Wired/Wireless remote control use is allowed only if indoor unit is ON
by the OnOff controller.
8IFOJOEPPSVOJUTBSF0''CZUIF0O0GGDPOUSPMMFSSFNPUFDPOUSPMVTF
is prohibited. Level 1
0''
ON
The use of wireless/wired remote controllers and external contact
control is prohibited. Level 2
ON
ON
No function
K3
0''0O0GGDPOUSPMMFSVTF
ON : Not use Onoff controller
"MMCVUUPOTEPOhUXPSL
K4
No function
Option switch
Indoor unit RMC(1)
matching address
A
ddress & option switch
R
emote control restriction
f
LEVEL 0
t
‘Allowed’ remote controller
f
LEVEL 1
t
Turned on by OnOff controller
– ‘Allowed’
t
Turned off by OnOff controller
– ‘Prohibited’
f
LEVEL 2
t
‘Prohibited’ remote controller