50 _ Troubleshooting
Check type
Check code
Checking method
Corrective actions
Thermistor
check
tC
1. Check the connections for the Thermistor connector
- Reconnect the Thermistor connector.
2. Check whether the Thermistor is operating normally.
- Measure the voltage between both ends of the Thermistor.
► Normal: 0.05 to 4.95V
- Measure the resistance between both ends of the Thermistor.
: Remove the connector before measuring. (See the Table right.)
Thermistor table
Temp(
℃
)
Resistance(kΩ)
5
125.814
10
98.36
15
77.48
20
61.477
25
49.12
30
39.51
35
31.985
40
26.053
45
21.347
50
17.59
55
14.573
60
12.136
65
10.157
70
8.541
- Faulty: Replace the Thermistor.
- Normal: Replace the Main PBA Assy.
Main-Sub PBA
Communication
check
AC
1. Check the connections between MAIN PBA CN802 connector and
Display Control Module CN101 connector.
- Reconnect the MAIN PBA CN802 connector and SUB PBA CN101
connector.
2. That check code is produced continuously after method 1 confirmation.
- Replace: Sub-Wire
3. That check code is produced continuously after method 2 confirmation.
- Replace: Sub-PBA
4. That check code is produced continuously after method 2 confirmation.
- Replace: Main-PBA