32 _ Disassembly and Reassembly
Part
Figure
Description
Assy sump
Preparation:
▪ Remove the Assy cover base.
- Refer to the “Assy cover base” disassembly section
to separate Assy cover base until step 2.
▪
Remove the case gear.
- Refer to the “Case gear etc” disassembly section to
separate Assy cover base until step 3.
▪
Remove the Circulation pump.
- Refer to the “Circulation pump” disassembly
section to separate Assy cover base until step 7.
▪
Remove the Drain pump.
- Refer to the “Drain pump” disassembly section to
separate Assy cover base until step 4.
1. Release Clamp.
Caution
Remove all water from the sump assembly before
removing the pump. Failure to do so will cause the
water to be released onto the floor. Make sure to use
a towel to cover the PBA Case & Electric parts to
prevent water damage to these parts.
2.
Remove the flat filter.
3. Remove the four (4) Screws.