Troubleshooting_51
Check type
Check code
Checking method
Corrective actions
Dry is not
satisfied.
None
6. Check the operation of the dispenser.
�
If rinse aids are not dispensed, a dry error may occur.
�
Because the dishes are heated and heat dried during the last drying cycle,
the dried state of plastic dishes may not be optimal.
- See “Detergent is not dispensed”
LED or Input
Key Fail
None
1. Check the connections for the Sub PBA connector
- Reconnect the Sub PBA connectors..
2. Check the LED and Input Key
1) Push ‘Hi-Temp Wash’ + ‘Sanitize’ + ‘Power Key’
�
Normal : All LED display
2) Push ‘Normal’~’Sanitize’
�
Normal : Each LED on
3) Every time you enter 'Delay Start'
�
Normal : Wash LED → Rinse LED → Dry LED `
→ Control Lock LED → Delay Start LED
→ Segment Dot → Rinse aid Refill LED
4) Push ‘Start’
�
Normal : LED Display ‘1234’
5) Push ‘Auto’
�
Normal : Version Display
- Faulty : Replace the Sub PBA.
3. Check the DC voltage of the Main PBA.
- See “Main PBA DC voltage error”.