Troubleshooting_41
Item
Related
Parts
Symptoms
Description
Manual Mode
Configuration
[AC circulation pump model]
1) Normal Key : Low(default) -> Hi ->Low -> Hi -> ..
2) Delicate Key : Low(default) -> Hi ->Low -> Hi -> ...
- Use Express60 Key if there is no Delicate Key
[ Alternation Location Change ]
- Each time Heavy Course Key is pressed, the alternation nozzle position can be set and it starts from its default position.
Unused alternation cannot be set.
No. 1 (default: the default position varies by model → No. 2 → No. 3 → No. 4 → No. 5 → No. 6 (max. alternation target
position: varies by model) → No. 1 → Please refer to [Dish Washer-Washing Performance Specifications-Distributor Control]
for the specifications of alternation position by model. (When the key is pressed, the current target alternation
position displays for 2 seconds.)
※
For models that do not use an alternating motor, entering this Key will trigger an Invalid tone.
※
When performing this STEP without performing STEP 1 as it has been already performed, calibrate the pressure in
the tub when restarting or operating the nozzle for the first time.
※
If STEP 1 has not been performed before, perform STEP 1 first.
(STEP 1 is not recognized as having been performed if STEP 1 is re-operated, STEP 6 has been performed or Auto
Mode has been enabled.)
※
For models with vane, the vane must move back and forth when the bottom alternation is in progress.
3. [Manual Mode STEP 3: inspect the heater]
- Set the alternation to the default position.
- Circulation pump: operate BDLC Model at 2400RPM, and AC model at LOW Power setting.
- Operate the heater after operating the circulation pump for 10 seconds.
- Turn the heater off when the max. temperature reaches 73 degrees or the max. operation time passes 10 minutes.
- During operation, the display alternates between the temperature of the heater and the current Step No.
※
When performing this STEP without performing STEP 1 as it has been already performed, calibrate the pressure in the
tub when restarting or operating the nozzle for the first time.
※
If STEP 1 has not been performed before, perform STEP 1 first. Only "3" blinks during STEP 1 operation
(no display of temperature).
(STEP 1 is not recognized as having been performed if STEP 1 is re-operated, STEP 6 has been performed or
Auto Mode has been enabled.)
4. [Manual Mode STEP 4: operate the dispenser]
- Operate the dispenser for 130 seconds.
5. [Manual Mode STEP 5: operate the fan]
- Operate the Fan Motor and Dry Actuator for 30 seconds. (Only for models with the relevant part)