50 _ Troubleshooting
Check type
Check code
Checking method
Corrective actions
Dry is not
satisfied.
None
1. Check whether Rinse Refill LED light or not.
- If Rinse Refill LED light, refill rinse in Dispenser.
2. Check the wire connections for the Dry Fan Motor.
- Reconnect the Dry Fan Motor connectors.
3. Check the resistance of the Dry Fan Motor coil.
(Remove the connector before measuring.)
�
Normal: Approx. 150 Ω
- Faulty: Replace the Dry Fan Motor assy.
4. Check the resistance of the Thermal Actuator.
(Remove the connector before measuring.)
�
Normal: Approx. 1.45 kΩ
- Faulty: Replace the Thermal Actuator.
5.Check the operation of the Dry Fan Motor Relay
: Check the operating voltage between the red wire of the C201 5pin
connector and the white wire of the CN202 9pin connector.
�
Normal: 120V (while operating)
- Faulty: Replace the Main PBA assy.
- Check voltage