30 _ Disassembly and Reassembly
Part
Figure
Description
Circulation Motor
Preparation:
• Disassemble the cover sump & cutter disposer and
shutter.
- Refer to each disassembly section.
1. Remove the circulation motor and capacitor
connection.
2.
Remove the four(4) screws holding the circulation
motor and the sump in place, and the one(1) screw
for earth connection from main wire-harness.
3.
Hold and pull out the circulation motor carefully to
remove it from the sump.
Caution
Remove the water from the sump assembly
beforeremoving the motor. Failure to do so will
cause to be released onto the floor.
Caution
Be careful not to break the oil seal when removing