![Samsung DW80K5050US Service Manual Download Page 14](http://html1.mh-extra.com/html/samsung/dw80k5050us/dw80k5050us_service-manual_4625920014.webp)
12 _ Disassembly and Reassembly
Part
Figure
Description
Door outer
Preparation:
• Make sure to disconnect the power.
• Remove the lower basket in the dishwasher.
• Cover the Assy sump with a towel to prevent
losing screws.
1. Open the door completely.
Remove the 12 screws holding the tub front, door
outer, and control panel in place.
Before removing the parts, place a cushioned
mat on the floor to prevent the parts from being
scratched.
After removing screws, make sure to hold the tub
front using your hand. It can prevent closing door
suddenly and harming you.
Caution
Do not place the removed screws on the door
inner. They may fall into the sump assy.2.
Remove the 12 screws (short one 8 pieces, long
one 4 pieces) which holding the door outer and
control panel in place.
2. Pull out the Door outer & the Assy control panel
carefully.
3. Remove the Assy control panel from Door outer.
( Pull out just a little)
Door Lock Switch
Preparation:
• Disassemble the frame front.
1. When removing the door latch, lift it up because
the latch is secured by one hooks.
Use a flat screwdriver to remove it.
2. Release the micro switch.