![Samsung DW80K5050US Service Manual Download Page 25](http://html1.mh-extra.com/html/samsung/dw80k5050us/dw80k5050us_service-manual_4625920025.webp)
Disassembly and Reassembly _ 23
Part
Figure
Description
Assy Case Brake
Outlet
Flow meter
Inlet
Preparation:
• Make sure to disconnect the power, water supply,
and drain hose connections.
• Remove the upper & lower baskets in the
dishwasher.
• Pull out the dishwasher carefully.
1. Remove the two (2) screws of the frame left.
2. Remove the frame left.
Caution
Make sure to wear gloves when removing it. Be
careful as the steel plate is sharp and may cut you.
3. . Remove cover brake by rotating.(counterclockwise)
Use a jig. If you do not have a jig, you can use a
needle nose pliers.(Be careful when removing the
cover as it is easily damaged.)
4.
Loosen the four (4) clamps and release the four (4)
hoses from the Assy case brake.
Caution
Water remaining in the Assy case sensor and Assy
case break will come out. Lay a towel on the floor to
absorb any water that may come out.