60 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 61
SECTION 4 |
Parameter Setup
4.6 GROUP 3 PARAMETER SET UP: INPUT LOW LIMIT
4.6.1 Programming Ranges and Default / Factory Preset Values of Parameters
under Group 3 - INPUT LOW LIMIT
Table 4.6 below gives details of programming ranges and default values of parameters under
Group 3 - INPUT LOW LIMIT. Refer to Fig 4.3 under Section 4.1.3.2 for Menu Map for navi-
gating through the various parameters under this Group.
Table 4.6 Group 3 Parameter Set Up: INPUT LOW LIMIT
(Refer to Menu Map at Fig 4.3, Section 4.1.3.2)
Screen
No.
Parameter
Setting range
EVO-1212F
EVO-1212F-HW EVO-2212
EVO-3012
EVO-1224F
EVO-1224F-HW EVO-2224
EVO-4024
1
RESET VOLTAGE
60.00 - 120.0V
(105.0V)
2
CUT OFF VOLT 1
60.00 - 120.0V
(100.0V)
3
DETECT TIME 1
0 - 2000 cycles
(300 cycles)
4
CUT OFF VOLT 2
60.00 - 120.0V
(95.0V)
5
DETECT TIME 2
0 - 2000 cycles
(60 cycles)
6
CUT OFF VOLT 3
60.00 - 120.0V
(90.0V)
7
DETECT TIME 3
0 - 2000 cycles
(1 cycle)
NOTE for Table 4.6: Values within brackets "( )" show the Default Setting.
4.6.2 Description of Parameters under Group 3 - INPUT LOW LIMIT
4.6.2.1 RESET VOLTAGE
(Table 4.6, Screen No. 1)
This is the reset voltage at which the unit will revert to "Charging Mode" after it has switched over to
"Inverting Mode" due to input voltage falling to "CUT-OFF VOLT 1/CUT-OFF VOLT 2/CUT-OFF VOLT3".
Password 8052
See Section 4.3.1
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
*
I N P U T
L O W L I M I T
ð
S e l e c t
P a r a m e t e r
I N P U T
L O W L I M I T
*
R E S E T
V O L T A G E
1 0 5 . 0 V
P a s s w o r d
k e y
i n
0 0 0 0
Down Key x 2 times
Enter Key
Enter Key
ð
S e l e c t
P a r a m e t e r
I N P U T
L O W L I M I T
*
R E S E T
V O L T A G E
1 0 5 . 0 V
ð
Enter Key
See Table 4.6, Screen No. 1
for programmable range
Summary of Contents for Evolution Series