26 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 27
SECTION 4 |
Parameter Setup
4.0 "SELECT GROUP" AND "SELECT PARAMETER" MENU MAPS
4.1.1 General Information
Up to 58 operating parameters can be programmed to suit the desired operating conditions.
The programmable parameters have been arranged under 7 Parameter Groups as per details at
Table 4.1 below. "Select Group" Menu Map for accessing the 7 Parameter Groups is shown at
Fig 4.1.
Table 4.1 List of Parameter Group Nos. 1 to 7
Parameter
Group No.
Parameter
Group Name
Description
"Select Group"
Menu Map
1
CHARGE CURVE
Parameters for battery charging/battery
protection
Fig 4.1
2
INPUT SETTING
Parameters for Grid/Generator input
current level, frequency range
3
INPUT LOW LIMIT
Parameters for Grid/Generator input low
voltage level
4
INPUT HIGH LIMIT
Parameters for Grid/Generator input high
voltage level
5
OTHER FUNCTION
Power Saving/Buzzer/Remote Switch/
Multi-function Relay/etc.
6
TIME SETTING
Real Time Clock setting
7
STOP SD CARD
Shown only when SD Card is inserted.
To stop SD Card accessed and to remove
the SD Card.
The 1st screen for Group 1 - CHARGE CURVE will be accessed when Enter key is pressed
momentarily from any of the Operating Mode Display Screens detailed at Table 3.1.
Fig 4.1 shows "Select Group" Menu Map for 7 Parameter Groups. Use the Up and Down
keys to navigate to the desired Parameter Group or the Back key to go back to the Operating
Mode Screen. Press Enter to access Parameters in the selected Parameter Group.
For explanation of the format of the "Select Group Screens" shown in Fig 4.1, consider
Group 1 Screen - CHARGE CURVE. The 1st line shows the action i.e. "Select Group". The 2
nd
line shows the name of the "Select Group" - CHARGE CURVE with an asterisk sign * against
it. The asterisk sign * indicates that this Group will be selected when Enter key is pressed.