4.4.2.17 GEN ON TIME
(Table 4.3, Screen No. 17)
This parameter is a Programmable Timer (0-240 min; Default: 60 min) that is used for program-
ming Automatic Starting and Stopping of Generator [Section 4.8.2.5.2(c)]. The Timer sets the
duration the Generator will remain ON from the time the Status Relay has been switched ON
(energized). The Status Relay will switch ON (energize) and start the Generator if the battery
voltage remains at threshold of “LOW VOLT ALARM” (Section 4.4.2.8) or lower for continuous
period = “GS DETECT TIME” (Section 4.4.2.16).
Password 8052
See Section 4.3.1
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
C H A R G E
C U R V E
*
B U L K C U R R E N T
2 0 A
ð
S e l e c t
P a r a m e t e r
C H A R G E
C U R V E
*
G E N O N
T I M E
6 0 m i n
P a s s w o r d
k e y
i n
0 0 0 0
Enter Key
Down Key x 16 times
Enter Key
ð
S e l e c t
P a r a m e t e r
C H A R G E
C U R V E
*
G E N O N
T I M E
6 0 m i n
4.4.2.18 GEN OFF DELAY
(Table 4.3, Screen No. 18)
This parameter is a Programmable Timer (0-240 min; Default: 60 min) that is used for the following:
•
Programming Automatic Starting and Stopping of Generator [Section
4.8.2.5.2(b)]:
The Timer sets the time period the batteries are required to remain charged
at the desired programmed level of voltage = “RESET VOLTAGE” (Section 4.4.2.7) or
higher before the Status Relay is switched OFF (de-energized) to stop the Generator.
•
Programming Option "1=Option2" in "ONLINE OPTION" (Section 4.4.2.14)
The Timer
sets the time period the batteries are required to remain charged at the desired pro-
grammed level of voltage = “RESET VOLTAGE” (Section 4.4.2.7) or higher before the
Transfer Relay is switched OFF (de-energized) to exit “Charging” Mode and revert to
“Inverting” Mode.
Password 8052
See Section 4.3.1
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
C H A R G E
C U R V E
*
B U L K C U R R E N T
2 0 A
ð
S e l e c t
P a r a m e t e r
C H A R G E
C U R V E
*
G E N O F F
D E L A Y
6 0 m i n
P a s s w o r d
k e y
i n
0 0 0 0
Enter Key
Down Key x 17 times
Enter Key
ð
S e l e c t
P a r a m e t e r
C H A R G E
C U R V E
*
G E N O F F
D E L A Y
6 0 m i n
SECTION 4 |
Parameter Setup
ð
See Table 4.3, Screen No. 17
for programmable range
ð
Enter Key
See Table 4.3, Screen No. 18
for programmable range
Enter Key