![background image](http://html1.mh-extra.com/html/sames-kremlin/nanogun-airmix-h2o/nanogun-airmix-h2o_user-manual_3696968040.webp)
Index revision : A
40
7118
10.14. Handle
•
Step 1
: Separate the barrel from the handle.
•
Step 2
:
Gun handle base
Unscrew the air nipple using a 16 Allen
wrench. Replace the seals every 12
months.
•
Step 3
: Unscrew the two screws (K35 x 14)
with a 2 crosspoint screwdriver. Upon each
screw removal, replace the fibre washers.
•
Step 4
: Raise the base in order to gain
access to the handle base joint. Replace
this joint every 12 months.
•
Step 5
: Remove the electrical connector
by pushing it to a point where the base
exits.
Replace the connector joint every 12
months.
•
Step 6
:
Replacement of the base:
unscrew
the ground wire screw using a 0 crosspoint
screwdriver, remove it and replace it.
For the reassembly step, proceed in the reverse
order.
Replace the pin of the connector in the
base polarising slot and re-screw the ground connection.
Coat the air nipple seals with dielectric grease.
Tighten the air nipple with 1.5 N.m of torque. Tighten the two screws (K35 x 14) with a 1.3 N.m
tightening torque.
Step 2
Step 3
Step 4
Step 6